Industrial valves: gate, globe, check, ball, butterfly and plug
Process valves for oil, gas, petrochemical, power and utility piping, supplied from Al Jubail. We source them from established manufacturers to API and ASME standards, check the documents, and supply the bolting and gaskets for the same joints.
Industrial valves are pressure-rated devices that isolate, regulate or stop reverse flow in process piping; JTE supplies them across Saudi Arabia. The main types are gate, globe, check, ball, butterfly, plug and needle valves. Each type has its own API design standard. ASME B16.34 sets the pressure-temperature rating by class, Class 150 to 2500 for most plant valves. We do not make valves; we source them to your data sheet and check the test and material certificates before dispatch.
- Valve types
- Gate, globe, check, ball, butterfly, plug and needle
- Design standards
- API 600, 602, 603, 623, 594, 608, 609, 599 and API 6D
- Ratings
- ASME B16.34 Class 150 to 2500; Class 800 for small forged valves
- End connections
- Flanged (ASME B16.5 / B16.47), butt-weld, socket-weld, threaded
- Body materials
- A216 WCB, A352 LCC, A351 CF8M, A105, A350 LF2, A182 F316
- Testing
- API 598 shell and seat tests; API 6D for pipeline valves
- Options
- Fire tested (API 607 / ISO 10497), low emission (API 624, API 641, ISO 15848-1), NACE MR0175
- Operation
- Handwheel, lever, gear operator or actuator

What we supply
- Gate and globe valves
- Cast steel to API 600, API 603 and API 623; forged small-bore valves to API 602
- Check valves
- Swing, lift and dual-plate wafer checks to API 594 or API 602
- Ball valves
- Floating and trunnion designs to API 608 or API 6D
- Butterfly valves
- Concentric, double offset and triple offset to API 609
- Plug and needle valves
- Plug valves to API 599; needle valves for instrument and sampling lines
- Valve bolting and gaskets
- Studs, nuts and gaskets for the valve flanges from our fastener range
Industrial valve types and their standards
Each valve type has a product standard that sets its design, sizes and classes. The ranges below are the scopes of the standards, not of any one maker’s catalog.
| Valve type | Typical standard | Sizes and classes in scope | Main job |
|---|---|---|---|
| Gate valve, bolted bonnet | API 600 | NPS 1 to 42; Class 150 to 2500 | On-off isolation, full bore, low pressure drop |
| Gate valve, corrosion resistant | API 603 | NPS 1/2 to 24; Class 150, 300, 600 | Stainless and alloy isolation in corrosive service |
| Compact forged gate, globe, check | API 602 | NPS 1/4 to 4; Class 150, 300, 600, 800, 1500 | Small bore: drains, vents, instrument roots |
| Globe valve | API 623 | NPS 2 to 24; Class 150 to 2500 | Throttling and frequent operation |
| Check valve (dual-plate, swing) | API 594 | NPS 2 to 48; Class 150 to 2500 | Prevents reverse flow |
| Ball valve, plant piping | API 608 | Flanged NPS 1/2 to 24, Class 150 to 600; SW and threaded NPS 1/4 to 2 up to Class 800 | Tight quarter-turn shut-off |
| Butterfly valve | API 609 | Category A NPS 2 to 60; Category B NPS 2 or 3 to 60 (by body and class), Class 150 to 600 | Large-bore isolation and control |
| Plug valve | API 599 | NPS 1/2 to 36; Class 150 to 2500 | Quarter-turn isolation, dirty or viscous fluids |
| Pipeline valve (ball, gate, plug, check) | API 6D | Class 150 to 2500 | Pipelines, scraper traps, terminals |
| Needle valve | Maker standard and project data sheet | Small bore, typically threaded or socket-weld | Fine regulation and instrument isolation |
Scopes summarized from the standards publishers’ listings. Editions used: API 600 14th (2021), API 602 2022, API 594 9th, API 608 2020, API 609 9th (2021), API 599 2020, API 623 2021. Confirm the edition your project specifies.
ASME B16.34 pressure ratings by class
A valve class is not a pressure. It points to a rating table that depends on the material group and the temperature. The values below are Standard Class ratings at -29 to 38 °C (-20 to 100 °F).
| Class | Group 1.1: A105, A216 WCB, A350 LF2 | Group 2.2: A351 CF8M, A182 F316 |
|---|---|---|
| Class 150 | 19.6 bar (285 psi) | 19.0 bar (about 275 psi) |
| Class 300 | 51.1 bar (740 psi) | 49.6 bar (about 720 psi) |
| Class 600 | 102.1 bar (1480 psi) | 99.3 bar (1440 psi) |
| Class 900 | 153.2 bar (2220 psi) | See the B16.34 Group 2.2 table |
| Class 1500 | 255.3 bar (3705 psi) | See the B16.34 Group 2.2 table |
| Class 2500 | 425.5 bar (6170 psi) | See the B16.34 Group 2.2 table |
Values as published from ASME B16.34 (2017 edition) by engineering references and valve makers; some maker charts round slightly differently (for example 51.0 bar for Class 300). Ratings fall as temperature rises: Group 1.1 Class 150 is 13.8 bar at 200 °C. Always check the edition your project names.
Saudi Arabia requirements for industrial valves
Saudi Aramco selects valves in SAES-L-108 and sets general, inspection and testing rules in 04-SAMSS-035 and 04-SAMSS-048. The points below come from unofficial copies; your purchase order and project specification control.
| Requirement | What it means |
|---|---|
| Approved manufacturers | SAES-L-108 (4.1) says valves are bought from approved manufacturers listed in SAES-L-102. State this on the RFQ so only qualifying makers are quoted. |
| Requisition references | SAES-L-108 (4.5) asks requisitions to reference 04-SAMSS-035 and 04-SAMSS-048. |
| Butterfly valves | Concentric API 609 Category A valves are limited to non-hydrocarbon service. Hydrocarbon high-performance valves are Category B offset designs, maximum Class 900, fire tested. |
| Check valves | Non-slam, spring-assisted checks at pump and compressor discharges. Wafer check bodies are not permitted in hydrocarbon service. |
| Instrument root valves | SAES-L-108 (7.11.1) calls for API 602 gate valves. |
| Body materials | No cast iron, ductile iron, brass or bronze in hydrocarbon service (SAES-L-108, 8.1). |
| Sour service | Wet sour service needs NACE MR0175/ISO 15156 materials, and 04-SAMSS-035 asks for compliant valves to be marked as such. |
| Operator force | 04-SAMSS-035 (8.4) limits hand force at the handwheel rim to 360 N (80 lb) at maximum differential pressure; quarter-turn gear operators are self-locking (8.2). |
| Testing and PMI | 04-SAMSS-048 holds shell tests 1 minute on NPS 2 and smaller, longer on larger valves. It requires PMI on all pressure-retaining parts of alloy valves. |
Based on unofficial copies of SAES-L-108 (11 October 2010), 04-SAMSS-035 (27 March 2017) and 04-SAMSS-048 (28 August 2013), which may be superseded; confirm against the current revision in your project specification.
Where industrial valves are used
Every process unit uses several valve types, each chosen for one job: isolate, throttle, prevent backflow or protect an instrument.
Process isolation
Gate and ball valves at unit battery limits, equipment nozzles and manifolds.
Pumps and compressors
Non-slam check valves on discharge lines and isolation valves on suction.
Instruments and sampling
API 602 root valves, needle valves and small ball valves for gauges and analyzers.
Steam and hot service
Globe and gate valves with hardfaced trim for steam, condensate and hot oil.
Cooling and seawater
Butterfly and check valves in large cooling water and desalination lines.
Shutdowns and turnarounds
Replacement valves with matching studs, nuts and gaskets for each joint.
Sourced and checked, not made by us
We source valves from established manufacturers to your data sheet and review the paperwork before anything ships.
- Maker’s API 598 or API 6D test records
- EN 10204 3.1 material certificates
- Data sheet check before quoting
- Third-party inspection on request
Bolting and gaskets for the same joints
A valve is only as tight as its flange joints. We supply the studs, nuts and gaskets with it.
- B7 and B7M studs with 2H or 2HM nuts
- Spiral wound and RTJ gaskets
- Flange isolation kits
- Studs cut and threaded at our factory in Al-Jubail
Industrial valve types explained
Industrial valves fall into three jobs: isolation (on-off), regulation (throttling) and non-return (check). Choosing the right type for the job matters more than any other decision on the data sheet.
Valves also split by motion. Linear valves, such as gate, globe and needle valves, move a stem up and down through several turns. Quarter-turn valves, such as ball, butterfly and plug valves, open fully with a 90 degree rotation.
Gate valves
A gate valve lifts a wedge or parallel gate clear of the flow path. Fully open, it gives a straight bore with very low pressure drop. It is for on-off duty only: used part-open, the flow erodes the seats and the gate vibrates.
Globe valves
A globe valve moves a disc onto a seat across the flow. The flow turns inside the body, so pressure drop is higher than in a gate valve. In exchange, the valve can throttle and keeps sealing after many cycles. Body patterns are straight, Y-pattern and angle.
Check valves
A check valve opens with forward flow and closes when flow reverses. It needs no operator. Swing checks hinge a disc and lift checks raise a disc or piston. Dual-plate wafer checks fold two spring-loaded half discs on a central pin.
Ball valves
A ball valve rotates a bored ball through 90 degrees. Soft seats give bubble-tight shut-off, and the valve opens and closes quickly. API 608 covers metal ball valves for plant piping, and API 6D covers pipeline ball valves.
Butterfly valves
A butterfly valve turns a disc on a shaft across the bore. It is short and light for its size, which makes it the usual choice for large cooling water, utility and low-pressure process lines. API 609 covers both concentric and offset designs.
Plug valves
A plug valve turns a tapered or cylindrical plug with a port through it. Lubricated plug valves inject sealant around the plug, and non-lubricated designs use a sleeve or liner. API 599 covers metal plug valves NPS 1/2 to 36 in Classes 150 to 2500.
Needle valves
A needle valve closes a slender, tapered stem tip into a small seat. Many turns of the handle move the tip a short distance, so flow can be set finely. They are used on instrument, gauge and sampling connections, usually with threaded or socket-weld ends. Ratings and materials follow the maker’s data sheet, so check them against your line class.
Ball valve designs: floating, trunnion, top entry and three-piece
The ball can float or be held on trunnions, and the body can be split in different ways. These choices decide the size and pressure range, the torque and how the valve is maintained.
- Full bore is needed where lines are pigged or pressure drop matters; reduced bore is lighter and cheaper.
- Soft seats (PTFE, reinforced PTFE, PEEK) give tight shut-off within the maker’s temperature limits; metal seats suit hot, abrasive or high-cycle duty.
Floating ball
In a floating ball valve the ball is held only by the two seats. Line pressure pushes the ball onto the downstream seat, which makes the seal. This is simple and reliable in small and medium sizes. As size and pressure rise, seat load and operating torque rise quickly. Large high-pressure valves therefore use a trunnion design.
Trunnion-mounted ball
A trunnion ball is fixed on top and bottom shafts. The seats are spring-loaded and pushed onto the ball, and each seat can seal on its own. That gives lower torque in large sizes and allows double block and bleed arrangements. API 608 covers both designs for plant piping but excludes trunnion valves with double piston effect seats, which are covered by API 6D.
Top entry and three-piece bodies
A top entry ball valve has one body with a cover on top. The ball and seats come out through the top, so the valve can be serviced while the body stays welded in the line. A three-piece valve has a center body bolted between two end pieces. With socket-weld or butt-weld ends, the center section can be swung out for seat replacement without cutting the pipe.
Double block and bleed (DBB) and double isolation and bleed (DIB)
API 6D defines DBB as a single valve with two seating surfaces that seals against pressure from both ends when closed. The cavity between the seats can be bled. DIB is a single valve with two seating surfaces, each of which seals on its own. A floating ball valve does not give DBB by itself. If your isolation philosophy calls for DBB, DIB-1 or DIB-2, write the exact term on the data sheet. The maker then offers the right seats.
Butterfly and check valve designs compared
Butterfly and check valves are often the largest valves in a plant. Their design types sound alike between makers, so it helps to know what the terms mean in the standards.
Concentric, double offset and triple offset butterfly valves
A concentric valve has the shaft through the center of the disc and a resilient (rubber or elastomer) seat. It is rated by cold working pressure, usually around Class 125 or 150 bolting, and serves water and utility lines. API 609 (9th edition, 2021) calls these Category A, from NPS 2 to 60.
A double offset (high-performance) valve moves the shaft behind the disc face and off the pipe centerline. The disc then cams away from the seat as it opens. A triple offset valve adds an angular offset: the cone-shaped seat and seal touch only in the last degree of closing. Triple offset valves are usually metal seated and suit hot and fire-tested duty. Offset designs are API 609 Category B, from NPS 2 or 3 up to NPS 60 depending on body type and class, in Classes 150, 300 and 600.
Wafer, lug and double flanged bodies
A wafer body is clamped between two pipe flanges by through-bolts. It is the lightest option but cannot hold pressure with one side open. A lug body has threaded lugs. It can be bolted to one flange and used at a line end, sometimes at a lower rating. A double flanged body bolts to each pipe flange separately.
Swing, lift and dual-plate check valves
API 594 Type A valves are short face-to-face designs in wafer, lug or double flanged bodies, including dual-plate checks. Type B valves are flanged or butt-weld swing checks with face-to-face dimensions to ASME B16.10. The standard runs from NPS 2 to 48 in Classes 150 to 2500.
Swing checks need enough flow to hold the disc fully open; at low flow the disc flutters and wears the hinge. Dual-plate checks close fast under spring load and reduce slam. Lift checks suit small bore and high pressure, and are covered with gate and globe valves in API 602.
Pressure-temperature ratings, dimensions and end connections
ASME B16.34 sets the pressure-temperature ratings, minimum wall thickness, materials and testing basis for flanged, threaded and welding-end steel valves. Most API valve standards refer to it, so the class on a gate, ball or check valve means the same thing.
The class is a dimensionless number. The allowed pressure depends on the material group and falls as temperature rises. Take a Class 150 carbon steel valve (Group 1.1, A105 or WCB). It is rated 19.6 bar at ambient, 13.8 bar at 200 °C and 6.5 bar at 400 °C. The same valve in Class 300 is rated 51.1, 43.8 and 34.7 bar at those temperatures.
Worked example
A hot oil line runs at 18 bar and 200 °C. A Class 150 carbon steel valve is rated 13.8 bar at 200 °C, so it is not enough. That holds even though 18 bar is below its 19.6 bar ambient rating. A Class 300 valve (43.8 bar at 200 °C) is the correct choice. The line class in your piping specification has already done this check, so use its class, not the operating pressure alone.
Class 800 and small forged valves
Class 800 is an intermediate class used for small forged valves with socket-weld and threaded ends. API 602 and API 608 list it, but it is not a flange class. A Class 800 valve with flanged ends is not a thing; flanged small valves are ordered in a B16.5 class.
Face-to-face dimensions to ASME B16.10
ASME B16.10 sets face-to-face dimensions for flanged steel valves and end-to-end dimensions for butt-weld valves. Pattern matters. An NPS 6 Class 150 gate valve is 267 mm face to face. An NPS 6 Class 150 ball valve is 267 mm in short pattern but 394 mm in long pattern. Short and long patterns are not interchangeable without changing the spool, so state the pattern on the order.
End connections
Flanged ends follow ASME B16.5 up to NPS 24 and B16.47 above. The facing (raised face, flat face or ring-type joint) must match the pipe flange. Butt-weld ends follow ASME B16.25 bevel details and must match the pipe schedule. Socket-weld and threaded ends are used on small bore, normally NPS 2 and smaller.
Body and trim materials
The body material must suit the fluid, the minimum and maximum temperature and the piping class. Castings and forgings of the same chemistry share a material group in ASME B16.34. A cast WCB valve and a forged A105 valve carry the same rating.
Trim means the wetted internal parts that do the sealing: stem, disc or wedge, seat rings and backseat. On API 600 gate valves, trim is ordered by a trim number.
API 600 trim numbers
The trim number describes the stem, the disc or wedge face and the seat face. The common ones are listed below as shown in a published API 600 trim chart. Some web pages give different mappings, so always confirm against the edition you buy to.
- Trim 1: 13Cr (type 410) stem, wedge and seat faces.
- Trim 5: hardfaced (cobalt-chromium alloy) wedge and seat faces, 13Cr stem.
- Trim 5A: nickel-chromium hardfaced wedge and seat faces, 13Cr stem.
- Trim 8: 13Cr stem and wedge, hardfaced seat faces. A common choice for general hydrocarbon and steam service.
- Trim 8A: as Trim 8 with nickel-chromium hardfacing on the seats.
- Trim 10: type 316 stem, wedge and seat faces.
- Trim 12: type 316 stem and wedge with hardfaced seat faces.
- Trim 16: type 316 stem with hardfaced wedge and seat faces.
Hardfacing
Hardfacing is a weld overlay that resists galling and erosion on seat faces. Saudi Aramco’s general valve specification, 04-SAMSS-035, names a cobalt-chromium hardfacing (alloy 6 type) as the default, with alloy 21 type where the product standard allows. Based on an unofficial copy of 04-SAMSS-035 (27 March 2017), which may be superseded; confirm against the current revision in your project specification.
| Material (cast / forged) | B16.34 group | Typical temperature range | Typical service |
|---|---|---|---|
| A216 WCB / A105 | 1.1 | -29 to 425 °C; not recommended for prolonged use above 425 °C | General hydrocarbon, water, steam and utilities |
| A352 LCC / A350 LF2 | 1.2 (LCC), 1.1 (LF2) | LCC impact tested at -46 °C; not above 345 °C | Low-temperature and depressurization service |
| A351 CF8M / A182 F316 | 2.2 | Down to cryogenic; to about 649 °C with carbon limits | Corrosive fluids, low temperature, clean service |
| A351 CF3M / A182 F316L | 2.2 (CF3M), 2.3 (F316L) | Typically to about 425 °C; B16.34 limit 454 °C (850 °F) | Corrosive service with welding |
| A217 WC6 / A182 F11 | 1.9 (1.25Cr-0.5Mo) | Up to about 593 °C | High-temperature steam |
A352 LCC Charpy tests at -46 °C: average at least 20 J (15 ft-lb), single value at least 16 J (12 ft-lb). Check NACE requirements separately for sour service.
Fire testing, fugitive emissions and sour service
Three extra qualifications are common on hydrocarbon valves: fire type-testing, low fugitive emissions and sour service materials. Each is a separate requirement and must be written on the order.
Fire tested valves: API 607 and ISO 10497
API 607 is a fire type-test for quarter-turn valves and valves with non-metallic seats. A test valve is closed, pressurized and burned for 30 minutes in a flame of about 750 to 1000 °C, then cooled and operated. Leakage through the seat and to the outside is measured against set limits. ISO 10497 is the closely aligned international fire test.
Fire-safe is a design qualification, not a test on each valve. Ask for the maker’s certificate covering the design, size range and class you are buying.
Fugitive emissions: API 622, API 624, API 641 and ISO 15848-1
Fugitive emission tests measure methane or helium leaking past the stem seal. API 622 qualifies the packing in a test fixture: 1,510 mechanical cycles and 5 thermal cycles to 260 °C (500 °F) at 600 psig, with methane. API 624 type-tests rising-stem valves with graphite packing: 310 cycles, 3 thermal cycles to 260 °C, and no more than 100 ppmv leakage with no gland adjustment. API 641 does the same for quarter-turn valves, with 610 cycles and a 100 ppmv limit.
ISO 15848-1 grades valves by tightness class, endurance class and temperature class. With methane, class AM allows up to 50 ppmv, BM up to 100 ppmv and CM up to 500 ppmv. For on-off valves, endurance class CO1 is 205 cycles, CO2 is 1,500 and CO3 is 2,500. A full designation therefore needs all three classes on the order.
Sour service: NACE MR0175/ISO 15156
Where wet hydrogen sulfide is present, materials must resist sulfide stress cracking. NACE MR0175/ISO 15156 governs oil and gas production; refineries often specify NACE MR0103/ISO 17945 instead. For carbon steel the familiar limit is 22 HRC maximum, including welds.
Compliance must be stated on the purchase order. Without it, standard castings, forgings, trim and bolting may exceed the hardness limits. Sour service applies to body, bonnet, trim and bolting. B7M studs with 2HM nuts are the usual choice where bolting may be exposed.
Valve operators: handwheel, lever, gear and actuator
The operator turns the stem. Manual valves use a handwheel (linear valves) or a lever (small quarter-turn valves). Larger or higher-pressure valves need a gearbox to keep hand force within limits, and automated valves use an actuator.
Saudi Aramco’s general valve specification, 04-SAMSS-035, sets a limit on hand force. Seating or unseating at maximum differential pressure must need no more than 360 N (80 lb) at the rim. Based on an unofficial copy of 04-SAMSS-035 (27 March 2017), which may be superseded; confirm against the current revision in your project specification. Makers size the gear operator from the valve torque, so give the maximum differential pressure on the RFQ.
- Lever: small quarter-turn valves; add a locking device where the valve must be secured.
- Handwheel: gate, globe and needle valves; check rim force at maximum differential pressure.
- Gear operator: bevel gear for large gate and globe valves, self-locking worm gear for ball, butterfly and plug valves.
- Pneumatic actuator: spring return (fail open or fail closed) or double acting; state the air supply pressure.
- Electric or hydraulic actuator: state power supply, enclosure and hazardous area class.
How to choose an industrial valve by service
Start from the job (isolate, throttle or prevent backflow), then the fluid, the line class and any special duty. The table gives a first selection that your piping specification will confirm.
| Service | Usual first choice | Points to specify |
|---|---|---|
| Hydrocarbon isolation, NPS 2 and larger | API 600 gate or API 608 / API 6D ball valve | Fire test, fugitive emission class, NACE if sour |
| Small-bore drains, vents and instrument roots | API 602 gate or globe, or small ball valve | Class 800 or 1500, socket-weld or threaded, seal weld if required |
| Throttling and flow control by hand | API 623 globe valve | Disc type, hardfaced trim, pressure drop |
| Pump and compressor discharge | Non-slam, spring-assisted check valve | Closing speed, body type allowed by your specification |
| Large cooling water and seawater lines | Butterfly valve (API 609) | Disc and seat materials for chlorides, lug or double flanged body |
| Steam and hot oil | Gate or globe with hardfaced trim (e.g. Trim 5 or 8) | Temperature rating of body group, bypass, drain |
| Low-temperature or depressurization lines | LCC or stainless steel body valve | Minimum design temperature, impact tests, extended bonnet |
| Pipelines and scraper traps | API 6D ball, gate or check valve | Full bore, DBB or DIB, buried or above ground |
| Dirty or viscous fluids | Plug valve (API 599) or metal-seated ball valve | Lubricated or sleeved, sealant compatibility |
| Instrument isolation and sampling | Needle valve or small ball valve | Ends, material and rating matching the tubing or pipe |
Inspection and testing of industrial valves
API 598 is the usual factory test standard for plant valves. Pipeline valves are tested to API 6D, and each valve is tested, not a sample. The tests are a shell test, a backseat test where the valve has one, and closure (seat) tests.
The shell test is a hydrostatic test at 1.5 times the 38 °C rating, with the valve part open. It proves the body and bonnet do not leak. The high-pressure closure test is at 1.1 times the rating, and a low-pressure closure test uses air or inert gas.
Receiving inspection checklist
- Nameplate and body markings match the order: maker, size, class, body material, trim, standard and, where required, NACE marking.
- Test certificates (API 598 or API 6D) list each valve by serial number.
- Material certificates (EN 10204 3.1) cover body, bonnet and other pressure parts, with heat numbers that match the castings or forgings.
- Fire test and fugitive emission type-test certificates cover the model, size and class supplied.
- Flange facing, finish and bore match the pipe flanges; butt-weld bevels and schedule match the pipe.
- End caps are in place, and soft-seated ball valves are delivered in the open position unless the maker says otherwise.
- Operator, locking device and actuator data match the data sheet.
Storage and site conditions in the Eastern Province
Coastal plants in Jubail Industrial City, Ras Al Khair and Ras Tanura combine heat, humidity, chlorides and fine sand. Keep valves in their end protectors, store them indoors or under cover off the ground, and protect exposed stems from sand. Soft seats, O-rings and plastic caps age in sun and heat, so avoid long outdoor storage.
Before installation, flush the line. Weld spatter, sand and mill scale are a common cause of seat damage on new ball valves. Tighten flange bolts in a cross pattern to the specified torque, and check gland packing after the first heat cycle.
| Valve size | Shell test minimum | Seat test minimum | Metal-seated leakage, liquid (except check) | Soft-seated leakage |
|---|---|---|---|---|
| NPS 2 and smaller | 15 s | 15 s | 0 drops (no visible leakage) | 0 |
| NPS 2 1/2 to 6 | 60 s | 60 s | 12 drops per minute | 0 |
| NPS 8 to 12 | 120 s | 120 s | 20 drops per minute | 0 |
| NPS 14 and larger | 300 s | 120 s | 28 drops per minute | 0 |
Metal-seated check valves are judged by volume instead: 3 cc per minute per inch of NPS for liquid. 16 drops equal about 1 ml. Saudi Aramco projects may require longer holds under 04-SAMSS-048. Based on an unofficial copy of 04-SAMSS-048 (28 August 2013), which may be superseded; confirm against the current revision in your project specification.
Industrial valve RFQ checklist and common mistakes
A complete RFQ line lets makers quote like for like and avoids a round of questions. Use the checklist below, or attach the data sheet from your piping specification.
Example RFQ line
Gate valve, API 600, NPS 6, Class 300, RF flanged to ASME B16.5, face-to-face to B16.10. Body A216 WCB, Trim 8, OS&Y bolted bonnet, handwheel. API 598 testing, fugitive emission to API 624, EN 10204 3.1 certificates, quantity 4.
Common mistakes
- Choosing the class from operating pressure alone, without checking the rating at design temperature.
- Ordering a gate valve to throttle flow; use a globe valve for throttling.
- Writing fire safe without naming the test standard.
- Writing low emission without naming API 624, API 641 or the ISO 15848-1 classes.
- Leaving out NACE on sour service, so standard-hardness parts are supplied.
- Mixing short and long pattern valves, so spool lengths no longer fit.
- Forgetting the matching gasket and bolting, which then holds up the installation.
- Valve type and design: for example gate, bolted bonnet, OS&Y, flexible wedge.
- Product standard and edition: API 600, 602, 608, 609, 594, 6D or other.
- Size (NPS or DN) and bore: full bore or reduced bore for ball and plug valves.
- Pressure class to ASME B16.34, and the design pressure and temperature.
- End connections and facing: RF, FF or RTJ flanged; butt-weld with schedule; socket-weld; threaded.
- Face-to-face pattern to ASME B16.10 where options exist (short or long).
- Body, bonnet and trim materials, including API 600 trim number or seat material.
- Special service: NACE MR0175/ISO 15156, low temperature, oxygen, hydrogen or other.
- Fire test (API 607 or ISO 10497) and fugitive emission (API 624, API 641 or ISO 15848-1 class) requirements.
- Operator: lever, handwheel, gear or actuator, with maximum differential pressure and locking needs.
- Testing and inspection: API 598 or API 6D, any extra tests, third-party inspection and documents required.
- Quantity, tag numbers and delivery point.
Industrial valve questions
What are the main types of industrial valves?
The main types are gate, globe, check, ball, butterfly, plug and needle valves. Gate, ball and plug valves isolate flow. Globe and needle valves regulate it. Check valves stop reverse flow. Butterfly valves isolate or control large lines. Each type has its own API product standard, and ASME B16.34 sets the pressure-temperature rating by class for most steel plant valves.
What is the difference between a gate valve and a globe valve?
A gate valve lifts a gate clear of the bore and gives a straight, full opening with low pressure drop. It is for on-off duty only. A globe valve seats a disc across a turning flow path. It has a higher pressure drop but can throttle and keeps sealing well after frequent operation. API 600 covers gate valves and API 623 covers globe valves.
Should I choose a floating or a trunnion ball valve?
Floating ball valves suit small and medium sizes and lower classes; line pressure pushes the ball onto the downstream seat. Trunnion valves hold the ball on shafts and use spring-loaded seats. They need less torque in large sizes and high classes, and allow double block and bleed. Your piping class or data sheet usually states which design is required.
What does Class 150 or Class 300 mean on a valve?
The class is a dimensionless rating designation from ASME B16.34. It points to a pressure-temperature table for the body material group. For example, a carbon steel (A105 or WCB) Class 150 valve is rated 19.6 bar at ambient temperature but 13.8 bar at 200 °C. Class 300 in the same material is rated 51.1 bar at ambient.
What is API 600 Trim 8?
In the published API 600 trim tables, Trim 8 has a 13Cr (type 410) stem and wedge with hardfaced seat faces. The hardfacing is usually a cobalt-chromium alloy that resists galling and erosion. Trim 8 is a common choice for general hydrocarbon and steam service. Confirm trim definitions against the API 600 edition named in your order.
What are API 609 Category A and Category B butterfly valves?
Category A valves are rated by the maker for cold working pressure and are usually concentric with a resilient seat, NPS 2 to 60. Category B valves are ASME class rated with an offset seat, such as double and triple offset designs. In the 2021 edition they run from NPS 2 or 3 to NPS 60 in Classes 150, 300 and 600. Many hydrocarbon specifications allow only Category B.
What does fire safe mean for a valve?
A fire-safe valve has a design that passed a fire type-test such as API 607 or ISO 10497. In API 607 the closed, pressurized valve burns for 30 minutes at about 750 to 1000 °C. It is then cooled and operated, with leakage measured throughout. It is a design qualification, so ask for the certificate covering the size and class you buy.
What are API 624 and API 641?
Both are fugitive emission type-tests using methane with a 100 ppmv leakage limit and no stem seal adjustment. API 624 covers rising-stem valves with graphite packing and runs 310 mechanical cycles with three thermal cycles to 260 °C. API 641 covers quarter-turn valves and runs 610 cycles. ISO 15848-1 is the international alternative with tightness, endurance and temperature classes.
Do valves for sour service need special materials?
Yes. With wet hydrogen sulfide, body, bonnet, trim and bolting must meet NACE MR0175/ISO 15156 for production service. Refinery specifications may call NACE MR0103/ISO 17945 instead. Carbon steel is limited to 22 HRC, including welds. The purchase order must state sour service, because standard parts may exceed the hardness limits.
What tests does API 598 require?
API 598 requires a hydrostatic shell test at 1.5 times the 38 °C rating and a backseat test where fitted. Closure tests follow: high-pressure liquid at 1.1 times the rating and low-pressure gas, depending on valve type. Soft-seated valves must show no visible seat leakage; metal-seated valves have small allowed rates by size.
Can a WCB carbon steel valve be used at low temperature?
Not below its rated minimum. A216 WCB tables start at -29 °C (-20 °F). For colder duty, such as depressurization or cold gas lines, specify A352 LCC (impact tested at -46 °C). A stainless steel body such as CF8M is another option. The piping class sets the minimum design temperature and the impact test requirements.
Does JTE manufacture valves?
No. JTE supplies industrial valves sourced from established manufacturers to your data sheet and project specification. We review the test and material certificates before dispatch and can arrange third-party inspection on request. We also supply the matching stud bolts, nuts and gaskets. Our factory in Al-Jubail cuts and threads the studs to length.
What information do I need to send for a valve quote?
Send the valve type, standard, size, class, end connection and facing, and body and trim materials. Add any special service (sour, low temperature, fire test, emissions), the operator, testing, documents and quantity. A data sheet or the valve list from your piping class is the quickest way to get a like-for-like quote.
Updated
Related
Flanges
Weld neck, slip-on, blind and socket-weld flanges for valve joints.
Spiral wound gaskets
The usual gasket for raised-face valve flanges.
Pipe fittings
Butt-weld and forged fittings for the same piping class.
Send your valve list