Flange isolation gasket kits for cathodic protection and dissimilar metals
Insulating gasket kits with sleeves and washers for every flange joint that must stop current flowing, supplied with matching stud bolts, plus spiral wound and ring joint gaskets, from Al Jubail.
A flange isolation kit electrically separates two flanges so that cathodic protection current, stray current or galvanic current cannot pass through the joint. The kit replaces the normal gasket with an insulating one and adds an insulating sleeve over every stud bolt and insulating washers under the nuts, so no metal path is left between the flanges. It is used at the boundary of a cathodically protected pipeline and where two different metals are bolted together.
- Kit types
- Type E (full face), Type F (raised face), Type D (ring joint groove), VCS sealing gasket kits
- Gasket materials
- Phenolic, neoprene-faced phenolic, G-10 / G-11 glass-reinforced epoxy (GRE), 316 stainless cored GRE
- Seals
- Nitrile, Viton (FKM) or spring-energised PTFE, to suit temperature and service
- Sleeves and washers
- G-10 or Mylar sleeves, G-10 insulating washers, plated steel washers
- Sizes
- ASME B16.5 and B16.47 flanges, Class 150 to 2500 depending on kit style
- Also supplied
- Spiral wound gaskets to ASME B16.20; R, RX and BX ring joint gaskets
Kit types explained
- Type E
- Full-face gasket with bolt holes; also keeps dirt out of the bore of the bolt holes
- Type F
- Fits inside the bolts on the raised face; located by the studs
- Type D
- Oval or octagonal insulating ring for ring-joint flanges
- VCS / sealing kits
- Stainless-cored GRE gasket with a seal, for higher pressure joints
- Double washer sets
- Insulating and steel washers on both sides isolate the bolts from both flanges
Isolation kit materials and limits
The retainer and seal materials set the temperature limit of the kit. Ratings vary between manufacturers, so the selected kit’s datasheet is always quoted with the offer.
| Component | Material | Typical use and limits |
|---|---|---|
| Gasket retainer | Plain phenolic | Low pressure water and gas; lower temperature limit than GRE |
| Gasket retainer | G-10 glass-reinforced epoxy | Standard for oil and gas; temperature rating per manufacturer, commonly 120 °C to 150 °C |
| Gasket retainer | G-11 glass-reinforced epoxy | Higher temperature service, up to about 200 °C on some kits |
| Seal | Nitrile | Hydrocarbons and water at moderate temperature |
| Seal | Viton (FKM) | Higher temperature and aggressive fluids |
| Seal | Spring-energised PTFE | Wide chemical resistance; Saudi Aramco limits spring-energised gaskets below 280 °F (138 °C) |
| Sleeves | G-10 or Mylar | Full-length sleeve over each stud bolt |
| Washers | G-10 insulating plus zinc-plated or stainless steel washers | Under each nut, one or both sides |
Material properties vary by kit and manufacturer; the selected product’s datasheet governs. G-7 retainers are not used with hydrocarbons.
Spiral wound and ring joint gaskets
For flanges that are not isolated we supply standard gaskets to ASME B16.20 with the rings and filler the service needs.
| Gasket | Requirement |
|---|---|
| Spiral wound, outer ring | Required on all sizes (Saudi Aramco SAES-L-109) |
| Spiral wound, inner ring | Required on 24 in. and larger, Class 900 and above where applicable, PTFE filler and vacuum service (SAES-L-109) |
| Spiral wound windings | 316 stainless for general hydrocarbon and steam service; rings match the flange material |
| Filler | Graphite for general service; PTFE not used in hydrocarbon or steam service |
| Ring joint gaskets | Octagonal Type R to ASME B16.20 for RTJ and API 6A flanges; RX and BX where specified |
Summarised from Saudi Aramco SAES-L-109 and ASME B16.20.
Saudi Arabia requirements for isolation kits
Saudi Aramco SAES-L-109 sets when insulating kits are used on flanged joints and how they fit with the cathodic protection standards.
| Requirement | What it means for the order |
|---|---|
| SAES-L-109, where kits are required | Approved insulation kits (insulating gasket, sleeves and washers) are used at dissimilar-metal flanged joints with a high galvanic corrosion potential, and at insulating joints for cathodic protection. |
| SAES-L-109, where kits are not required | For example dry hydrocarbon gas in dry areas, temperatures above the non-metallic gasket limit, or flammable services where external bonding would make the kit ineffective. |
| Insulating joints | Insulating joints meet the mechanical requirements of SAES-L-109 and are installed as the cathodic protection or stray current protection standards require. |
| Washers | Flat washers under nuts are required on insulating flanges. |
| Spring-energised seals | Spring-energised gaskets are not permitted at 280 °F (138 °C) and above, and only fire-safe gaskets are used in refineries and gas plants. |
| Vendor status | JTE Fasteners is ISO 9001 certified and registered as an approved vendor with Saudi Aramco and SABIC. |
Summarised from Saudi Aramco SAES-L-109. The kit type and materials follow the project’s cathodic protection design; send the datasheet with the enquiry.
Where isolation kits are used
Any flange that sits on the boundary of a cathodic protection system, or joins two different metals, needs isolating.
Pipeline CP boundaries
Where a buried, cathodically protected pipeline enters a plant or station.
Dissimilar metal joints
Carbon steel to stainless, duplex, copper-nickel or titanium flanges.
Pump and equipment nozzles
Isolating equipment from a protected line.
Loading lines and jetties
Stray current protection on marine loading lines.
Kits with bolting
Sleeved stud bolts and nuts supplied with the kit.
Shutdown packs
Kits and gaskets tagged by joint for planned work.
Supplied ready to install
An isolation kit only works if every bolt is sleeved and every washer is in place. We supply complete sets.
- Gasket, sleeves and washers counted per flange
- Stud bolts and nuts in the right length for the kit thickness
- Kits packed and labelled per joint
- Datasheet with temperature and pressure ratings
Documents with every order
Kits are traceable to the manufacturer’s material and test data.
- Manufacturer’s datasheet and certificate
- Material certificates for steel washers and studs
- EN 10204 3.1 MTC for bolting
- Packing list per joint
Flange isolation kit questions
What is in a flange isolation kit?
An insulating gasket, a full-length insulating sleeve for each stud bolt, and for each bolt two insulating washers and two steel washers in a double-washer set. Together they stop any metal-to-metal contact between the two flanges.
What is the difference between Type E and Type F kits?
A Type E gasket is full face, the same outside diameter as the flange with bolt holes. A Type F gasket sits inside the bolt circle on the raised face and is located by the studs. Type D is an insulating ring for ring-joint flanges.
When does Saudi Aramco require isolation kits?
SAES-L-109 calls for approved insulation kits at dissimilar-metal flanged joints with high galvanic corrosion potential and at insulating joints for cathodic protection, with some exceptions such as dry hydrocarbon gas in dry areas.
What temperature can a G-10 isolation kit take?
It depends on the manufacturer and seal. G-10 retainers are commonly rated from about 120 °C to 150 °C, and G-11 to about 200 °C. We quote the selected kit’s datasheet rating for your service.
Why use a single-washer kit underground?
On buried flanges a single-washer set lets cathodic protection current reach the bolts and nuts on one side, protecting them from corrosion, while the joint stays isolated.
Do you supply the stud bolts for isolation kits?
Yes. Insulating gaskets and washers add thickness, so we supply stud bolts at the correct length with the kit, in B7, B7M or coated bolting as the line class requires.
Updated
Related
Gaskets and rings
Spiral wound, RTJ and soft gaskets.
Stud bolts
B7, B7M, L7 and coated studs.
Flanges
ASME B16.5 and B16.47 flanges.
Need isolation kits?