Shear connectors and weld studs for drawn-arc stud welding
Headed shear connectors for composite steel and concrete construction and threaded weld studs for embed plates and equipment, to ISO 13918 or AWS D1.1, supplied with the matching ceramic ferrules.
A shear connector is a headed steel stud welded to a steel beam so that the concrete slab above acts together with the beam. They are welded by the drawn-arc process: the stud is lifted to draw an arc, plunged into the molten pool, and a ceramic ferrule shapes the weld. ISO 13918 covers the studs and ferrules, with type SD for headed shear connectors, and AWS D1.1 Type B headed studs have a 65 ksi (450 MPa) minimum tensile strength. Carbon steel studs are cold-finished low-carbon bar to ASTM A108, grades 1010 to 1020.
- Standards
- ISO 13918:2017 + A1:2021; AWS D1.1 Clause 9 (stud welding)
- Shear connectors
- ISO 13918 type SD; AWS D1.1 Type B headed studs
- Threaded studs
- ISO 13918 types PD (partly threaded) and RD (reduced shaft)
- Material
- ASTM A108 cold-finished steel, grades 1010 to 1020; stainless on request
- Diameters
- Shear connectors 16, 19, 22 and 25 mm; 3/4 and 7/8 in.
- Ferrules
- Ceramic ferrules matched to stud diameter and base

What we supply
- Shear connectors
- Headed studs for composite beams and decks
- Threaded studs
- PD and RD studs for embed plates and brackets
- Ceramic ferrules
- Flat, vertical and through-deck ferrules
- Mixed orders
- Studs packed by diameter and length per area
AWS D1.1 stud types
AWS D1.1 sorts weld studs by use. Type B is the headed stud used as a shear connector and concrete anchor.
| Type | Use | Tensile min | Yield min | Elongation min (2 in.) |
|---|---|---|---|---|
| Type A | General purpose, not shear transfer | 61 ksi (420 MPa) | 49 ksi (340 MPa) | 17% |
| Type B | Headed shear connectors and concrete anchors | 65 ksi (450 MPa) | 51 ksi (350 MPa) | 20% |
Values summarised from AWS D1.1 as published by stud manufacturers. Types C (deformed bar anchors) and D (added in D1.1:2025) are not shown. Stud size, spacing and capacity are designed by the structural engineer.
ISO 13918 drawn-arc stud types
ISO 13918 identifies each stud type by a letter code, for example SD for headed shear connectors. The types below are drawn-arc studs, welded with a ceramic ferrule.
| Type | Description | Typical use |
|---|---|---|
| SD | Headed shear connector | Composite beams, decks and bridges |
| PD | Partly threaded stud | Bolting brackets and equipment to steel |
| RD | Threaded stud with reduced shaft | Threaded fixings on embed plates |
| UD | Unthreaded stud | Pins and anchors |
Shear connectors are commonly 16, 19, 22 or 25 mm, with 19 mm the usual size for welding through steel decking.
Saudi Arabia requirements for shear connectors
Saudi Aramco covers shear connectors in its structural steel standard 12-SAMSS-007. The first point is from an unofficial copy of the 2011 issue, the second compares it with the current AWS clause, and the third is a general welding rule; confirm against the current revision.
| Requirement | What it means for the order |
|---|---|
| Headed studs (12-SAMSS-007, 2011 copy) | Shear connectors for composite construction are headed studs to ASTM A108 grades 1010 to 1020, AWS D1.1 Type B. |
| Welding code | The 2011 copy of 12-SAMSS-007 cites AWS D1.1 Section 7; in AWS D1.1:2020 and later, stud welding is Clause 9. |
| Qualification (AWS D1.1 / ISO 14555, not a 12-SAMSS-007 clause) | Welding procedure and stud qualification are the fabricator’s responsibility under AWS D1.1 or ISO 14555. |
Based on an unofficial copy of 12-SAMSS-007 (2011), which may be superseded; confirm against the current revision in your project specification. JTE supplies studs and ferrules; welding is done by the steel fabricator or erector.
Where weld studs are used
Drawn-arc studs are the structural stud welding process, from composite decks to embed plates.
Composite floors
Shear connectors on beams under concrete slabs.
Embed plates
Headed studs anchoring plates into concrete.
Bridges
Shear connectors on steel girders.
Threaded fixings
PD and RD studs for brackets and supports.
Equipment
Studs for mounting equipment to steel.
Site packs
Studs and ferrules packed per area.
Studs and ferrules together
Every drawn-arc stud needs a ferrule matched to its diameter and base, so we supply both.
- Flat ferrules for down-hand welding
- Vertical ferrules for wall welding
- Through-deck ferrules
- Studs by diameter and length
- Stainless studs on request
Documents with every order
Stud material and properties are certified for the fabricator’s records.
- EN 10204 3.1 MTC
- Mechanical test results
- Dimensional check
- Lot traceability
- 3.2 with third-party inspection
Weld stud and shear connector questions
What is a shear connector?
A headed steel stud welded to the top of a steel beam so that the concrete slab and the beam act together as one composite section.
What is an AWS Type B stud?
A headed stud used for shear connectors and concrete anchorage, with a 65 ksi (450 MPa) minimum tensile strength, 51 ksi yield and 20% elongation.
What material are shear studs made from?
Cold-finished low-carbon steel bar to ASTM A108, grades 1010 to 1020. Stainless studs are used in some outdoor or marine settings.
Why do weld studs need ceramic ferrules?
In drawn-arc welding, the ferrule contains the molten metal, shapes the weld fillet and shields the arc. It is broken off and discarded after welding.
Do you weld the studs?
No. We supply studs and ferrules; welding and qualification are done by the steel fabricator or erector under AWS D1.1 or ISO 14555.
Updated
Related
Structural steel and bars
Plates, sections and bars.
F3125 structural bolts
A325 and A490 bolts for steel connections.
Anchor bolts
Cast-in anchor bolts for foundations.
Need shear connectors for a project?