Inconel, Monel and Hastelloy fasteners for seawater, sour and acid service
Nickel alloy stud bolts, bolts and nuts in Alloy 625, 718, 400, K-500 and C-276 for Saudi plants where carbon and stainless steel bolting corrodes, supplied from Al Jubail with full material traceability.
Nickel alloy fasteners are used where steel and stainless bolting would corrode, crack or lose strength. Alloy 625 and C-276 resist pitting and crevice corrosion in seawater and chlorides, Monel 400 is one of the few metals used in hydrofluoric acid service, and the age-hardened grades 718 and K-500 give high strength where super duplex is not strong enough. JTE supplies them as studs, bolts and nuts made from certified bar, with the alloy, heat number and hardness on the certificate.
- Alloys
- Inconel 625 (UNS N06625), Inconel 718 (N07718), Monel 400 (N04400), Monel K-500 (N05500), Hastelloy C-276 (N10276)
- Fastener specs
- ASTM F468 bolts and studs, ASTM F467 nuts, or the purchaser’s specification
- Bar specs
- ASTM B446 (625), B637 / AMS 5662-5663 / API 6ACRA (718), B164 (400), B865 (K-500), B574 (C-276)
- Products
- Stud bolts, hex bolts, heavy hex nuts, washers, threaded rod, machined specials
- Sizes
- Inch and metric, to ASME B16.5 / B16.47 flange bolting lengths or drawing
- Documents
- EN 10204 3.1 MTC with heat number and hardness; 3.2 with third-party inspection on request
What each alloy is chosen for
- Alloy 625
- Seawater, brine and chloride service; resists pitting, crevice corrosion and chloride stress corrosion cracking
- Alloy 718
- High-strength bolting where super duplex is not strong enough, including oilfield sour service within its hardness limit
- Monel 400
- Hydrofluoric acid alkylation units and seawater, where oxygen is excluded
- Monel K-500
- High-strength seawater bolting, pump and valve fasteners
- Hastelloy C-276
- Strong acids, chlorides and sour oilfield environments
Nickel alloy fastener properties
Minimum properties for fasteners and the bar they are made from. Age-hardened alloys (718, K-500) are far stronger than the solid-solution alloys (625, 400, C-276), so the alloy and condition must both be named on the order.
| Alloy and condition | Min tensile | Min yield | Hardness |
|---|---|---|---|
| Alloy 625, annealed (ASTM F468 / B446 Grade 1, up to 4 in.) | 120 ksi (827 MPa) | 60 ksi (414 MPa) | 85 HRB to 35 HRC (F468) |
| Alloy 718, solution annealed and aged (API 6ACRA 120K grade) | 150 ksi (1034 MPa) | 120 to 145 ksi (827 to 1000 MPa) | 32 to 40 HRC |
| Monel 400, cold worked and stress relieved (ASTM F468, 1/4 to 3/4 in.) | 80 to 130 ksi | 40 ksi (276 MPa) | 75 HRB to 25 HRC |
| Monel K-500, solution annealed and aged (ASTM F468, up to 7/8 in.) | 130 to 180 ksi | 90 ksi (621 MPa) | 24 to 37 HRC |
| Hastelloy C-276 (ASTM F468) | 110 to 140 ksi | 45 ksi (310 MPa) | 20 to 32 HRC |
Values summarised from ASTM F468, ASTM B446 and producer data for API 6ACRA Alloy 718. Larger diameters can have lower minimums; the governing edition and size band are confirmed on the order and certificate.
Sour service (NACE MR0175 / ISO 15156-3)
In wet H2S service the hardness and heat-treated condition of nickel alloy bolting are limited. JTE supplies material to the condition and hardness the order calls for and reports hardness on the certificate; the suitability for a given environment remains the plant’s material selection.
| Alloy | Condition | Hardness limit |
|---|---|---|
| Alloy 625 | Annealed or solution annealed | No hardness limit stated for annealed material |
| Hastelloy C-276 | Annealed or solution annealed | No hardness limit stated for annealed material |
| Alloy 718 | Solution annealed and aged | Max 40 HRC |
| Monel K-500 | Hot worked and aged, solution annealed, or solution annealed and aged | Max 35 HRC |
K-500 bolts to ASTM F468 may be up to 37 HRC, so lots for sour service are hardness checked against the 35 HRC limit. Limits as published in ISO 15156-3 Annex A; confirm against the edition named in the project specification.
Saudi Arabia requirements for nickel alloy bolting
Saudi Aramco and SABIC piping standards use alloy steel bolting (B7, B7M, L7, B16) as the default. Nickel alloys are a project material selection for environments those grades cannot handle.
| Requirement | What it means for the order |
|---|---|
| Saudi Aramco SAES-L-109, aggressive external environments | For offshore and underground bolting, corrosion-resistant alloy bolting is one of the permitted options, alongside ceramic-fluoropolymer coated B7 to 09-SAMSS-107. The alloy is chosen by the project’s material selection. |
| Material selection | The line class or datasheet names the alloy and condition. We supply exactly that grade and do not substitute between nickel alloys. |
| Sour service | Where the line is in wet sour service, hardness is controlled to NACE MR0175 / ISO 15156-3 limits and reported on the MTC. |
| Documents | EN 10204 3.1 certificate with the bar heat number, chemical analysis and mechanical results; PMI (positive material identification) on request. |
| Vendor status | JTE Fasteners is ISO 9001 certified and registered as an approved vendor with Saudi Aramco and SABIC. |
Summarised from Saudi Aramco SAES-L-109 (bolting for aggressive environments). Project specifications and SAMSS documents take precedence; send them with the enquiry.
Where nickel alloy bolting is used
Nickel alloy bolting is specified where a bolt failure is expensive: seawater systems, acid units and sour equipment.
Seawater intake and cooling water
Flanges and pumps on seawater lines at Jubail and Ras Al Khair plants, commonly in Alloy 625 or K-500.
HF alkylation units
Monel 400 bolting in hydrofluoric acid service where oxygen is kept out.
Desalination equipment
Brine heaters, pumps and valves in thermal and reverse osmosis plants.
Sour oil and gas
Age-hardened 718 studs for wellhead and valve bolting within the sour-service hardness limit.
Chemical process plant
C-276 bolting on equipment handling strong acids and chlorides.
Traceable spares
Replacement studs and nuts made to match an existing alloy joint, with PMI on request.
Avoiding galling on nickel alloy threads
Nickel alloys gall easily when the stud and nut are the same alloy and are tightened fast. We supply sets ready for controlled assembly.
- Thread lubricant or anti-seize suited to the alloy
- Nut and stud hardness kept apart where the spec allows
- Coarse threads unless fine is specified
- Slow, controlled tightening advised
Documents with every order
Nickel alloy bolting is usually bought for critical joints, so the paperwork matters as much as the parts.
- EN 10204 3.1 MTC with bar heat number
- Chemical analysis and mechanical results
- Hardness results
- PMI report on request
- 3.2 with third-party inspection
Nickel alloy fastener questions
Which nickel alloy is best for seawater bolting?
Alloy 625 is the usual choice where corrosion resistance matters more than strength, because it resists pitting and crevice corrosion in seawater. Monel K-500 or Alloy 718 are used where higher bolt strength is needed. The project material selection decides; we supply the alloy specified.
What is the difference between Monel 400 and Monel K-500?
Both are nickel-copper alloys. K-500 adds aluminium and titanium and is age hardened, so its minimum yield is roughly double that of Monel 400. Monel 400 is softer and is used mainly for its corrosion resistance, for example in hydrofluoric acid units.
Are Inconel 718 bolts acceptable for sour service?
Alloy 718 in the solution annealed and aged condition is listed in ISO 15156-3 with a maximum hardness of 40 HRC. The 120K oilfield grade (32 to 40 HRC) sits within that limit; higher-strength grades can exceed it, so the hardness is checked against the order.
Which ASTM standard covers nickel alloy bolts and nuts?
ASTM F468 covers nonferrous bolts, screws and studs, including Alloy 400, K-500, 625 and C-276, and ASTM F467 covers the matching nuts. Alloy 718 fasteners are normally made from ASTM B637, AMS or API 6ACRA bar to the purchaser’s specification.
Does Saudi Aramco require nickel alloy bolting?
No single Aramco rule requires it. SAES-L-109 allows corrosion-resistant alloy bolting as one option for aggressive external environments such as offshore and underground piping, and the alloy is chosen in the project’s material selection.
How do I stop nickel alloy studs galling?
Use a suitable thread lubricant, tighten slowly, keep coarse threads, and where the specification allows, use a nut and stud of different hardness. We can supply studs and nuts with lubricant or coating to suit your procedure.
Updated
Related
Exotic alloy fasteners
Duplex, super duplex, titanium and nickel alloy bolting.
B8M Class 2 stud bolts
Strain-hardened 316 stainless studs with higher strength.
Power and desalination
Bolting for seawater, brine and steam systems.
Need nickel alloy bolting?
Send the alloy, condition, sizes and line class: we quote with the bar specification and certificate stated.